{"id":1442,"date":"2023-09-29T10:50:45","date_gmt":"2023-09-29T07:20:45","guid":{"rendered":"https:\/\/amkahex.com\/software\/"},"modified":"2024-12-05T16:02:13","modified_gmt":"2024-12-05T12:32:13","slug":"software","status":"publish","type":"page","link":"https:\/\/amkahex.com\/en\/software\/","title":{"rendered":"Software"},"content":{"rendered":"\n\t<section class=\"section\" id=\"section_1997574956\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"container section-title-container\" ><h3 class=\"section-title section-title-normal\"><b aria-hidden=\"true\"><\/b><span class=\"section-title-main\" >Software<\/span><b aria-hidden=\"true\"><\/b><\/h3><\/div>\n<div class=\"row align-bottom align-center\"  id=\"row-909941514\">\n\n\t<div id=\"col-1507974250\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<div class=\"row align-bottom\"  id=\"row-1566301100\">\n\n\t<div id=\"col-2002115360\" class=\"col medium-12 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p style=\"text-align: justify;\">The need for precise computational, theoretical, and academic design of heat exchangers has led to the development of various references, codes, standards, and even mathematical theories for the design and construction of heat exchangers. For more information, you can refer to the latest scientific articles and achievements of global experts in the download section.<\/p>\n<p>The presence of two-phase flow, oil-contaminated fluid, and the use of multi-component refrigerants inside the tubes, along with the lack of a unified calculation method, has made the design of shell and tube heat exchangers specifically for air conditioning systems one of the most specialized and knowledge-based areas in this field.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1846847707\" class=\"col medium-12 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner text-center\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_348184030\">\n\t\t\t\t\t\t<div data-animate=\"bounceInDown\">\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1240\" height=\"565\" src=\"https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/amka-software-05.jpg\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/amka-software-05.jpg 1240w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/amka-software-05-300x137.jpg 300w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/amka-software-05-1024x467.jpg 1024w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/amka-software-05-768x350.jpg 768w\" sizes=\"auto, (max-width: 1240px) 100vw, 1240px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t<\/div>\t\t\t\t\t\t\n<style>\n#image_348184030 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1846847707 > .col-inner {\n  margin: -70px 0px 0px 0px;\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\t<div id=\"col-1924754831\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p style=\"text-align: justify;\">Moreover, the existence of refrigeration compressors and the importance of oil return, pressure drop, and flow rate emphasize that the design and construction of shell and tube heat exchangers for air conditioning systems is a completely specialized, separate, and distinct field from the general design of liquid-gas heat exchangers.<\/p>\n<p>Therefore, various commercial software and coding are available and used by Asamobadel Caspian Company for calculating shell and tube heat exchangers.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1997574956 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section\" id=\"section_1878157462\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row align-middle align-center\"  id=\"row-928478965\">\n\n\t<div id=\"col-1868415669\" class=\"col medium-8 small-12 large-6\"  data-animate=\"bounceInRight\">\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"text-506121475\" class=\"text\">\n\t\t\n<p><strong>If the design of the heat exchanger is entrusted to Asamobadel Caspian Company:<\/strong><\/p>\n\t\t\n<style>\n#text-506121475 {\n  font-size: 1.1rem;\n}\n<\/style>\n\t<\/div>\n\t\n<p style=\"text-align: justify;\">The capacity design will be carried out according to the ARI 550\/590-2015 standard, and changes in input conditions can be made specifically upon customer request.<\/p>\n<p>The design and construction of shell and tube heat exchangers at AMKA will be entirely based on the TEMA Standard, ninth edition, unless the customer&#8217;s request contradicts the standard or specific specifications such as drawings or codes are mentioned in the proforma invoice. <\/p>\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1868415669 > .col-inner {\n  padding: 10px 10px 0px 10px;\n  margin: -42px -42px 0px 0px;\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\t<div id=\"col-598041394\" class=\"col medium-11 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_366214645\">\n\t\t\t\t\t\t<div data-animate=\"bounceInLeft\">\t\t<div class=\"img-inner box-shadow-2 box-shadow-2-hover dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"452\" src=\"https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/amka-software-01.jpg\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/amka-software-01.jpg 800w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/amka-software-01-300x170.jpg 300w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/amka-software-01-768x434.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t<\/div>\t\t\t\t\t\t\n<style>\n#image_366214645 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1878157462 {\n  padding-top: 40px;\n  padding-bottom: 40px;\n  background-color: rgb(129, 195, 45);\n}\n@media (min-width:550px) {\n  #section_1878157462 {\n    padding-top: 80px;\n    padding-bottom: 80px;\n  }\n}\n@media (min-width:850px) {\n  #section_1878157462 {\n    padding-top: 20px;\n    padding-bottom: 20px;\n  }\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section\" id=\"section_233853111\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row align-center\"  id=\"row-1536850563\">\n\n\t<div id=\"col-1504862160\" class=\"col medium-5 small-12 large-5\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_104771431\">\n\t\t\t\t\t\t<div data-animate=\"flipInX\">\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"907\" height=\"827\" src=\"https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/oil-cooler-10.jpg\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/oil-cooler-10.jpg 907w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/oil-cooler-10-300x274.jpg 300w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/oil-cooler-10-768x700.jpg 768w\" sizes=\"auto, (max-width: 907px) 100vw, 907px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t<\/div>\t\t\t\t\t\t\n<style>\n#image_104771431 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1504862160 > .col-inner {\n  padding: 0px 0px 0px 1px;\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\t<div id=\"col-964564480\" class=\"col medium-6 small-12 large-6\"  data-animate=\"bounceIn\">\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"text-314578694\" class=\"text\">\n\t\t\n<p><strong>Capacity design and calculations of heat exchangers are performed using software :<\/strong><\/p>\n\t\t\n<style>\n#text-314578694 {\n  font-size: 1.05rem;\n}\n<\/style>\n\t<\/div>\n\t\n<p>Capacity design and calculations of heat exchangers are performed using software with EUROVENT certification, some of which are listed below:<\/p>\n<ul>\n<li>IMST<\/li>\n<li>UNILAB SHELL<\/li>\n<li>WEILAND<\/li>\n<li>ASPEN B JACK<\/li>\n<li>HTRI <\/li>\n<li>ASPEN EDR<\/li>\n<\/ul>\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-964564480 > .col-inner {\n  padding: 0px 0px 0px 0;\n}\n@media (min-width:550px) {\n  #col-964564480 > .col-inner {\n    padding: 50px 0px 0px 20px;\n  }\n}\n@media (min-width:850px) {\n  #col-964564480 > .col-inner {\n    padding: 0px 0px 0px 50px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_233853111 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section\" id=\"section_894428386\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row align-equal align-center\"  id=\"row-1028046696\">\n\n\t<div id=\"col-1691953710\" class=\"col medium-7 small-12 large-6\"  data-animate=\"bounceIn\">\n\t\t\t\t<div class=\"col-inner text-left\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"text-268046653\" class=\"text\">\n\t\t\n<p>ASME Section VIII Hydrostatic Test<\/p>\n\t\t\n<style>\n#text-268046653 {\n  font-size: 1.5rem;\n  text-align: center;\n  color: rgb(255,255,255);\n}\n#text-268046653 > * {\n  color: rgb(255,255,255);\n}\n<\/style>\n\t<\/div>\n\t\n\t<div id=\"text-576073780\" class=\"text\">\n\t\t\n<p style=\"text-align: left;\">Hydrostatic testing based on the ASME Section VIII standard is conducted at 1.5 times the operating pressure of the heat exchanger for a duration of 30 minutes, depending on the type of refrigerant.<\/p>\n<p style=\"text-align: left;\">For evaporators, the shell is tested at 250 PSI.<\/p>\n<p style=\"text-align: left;\">For condensers, the pressure varies from 300 to 900 PSI depending on the type of gas.<\/p>\n\t\t\n<style>\n#text-576073780 {\n  text-align: right;\n  color: rgb(255,255,255);\n}\n#text-576073780 > * {\n  color: rgb(255,255,255);\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-670399444\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_919046260\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"925\" height=\"790\" src=\"https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/condenser-12.jpg\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/condenser-12.jpg 925w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/condenser-12-300x256.jpg 300w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/condenser-12-768x656.jpg 768w\" sizes=\"auto, (max-width: 925px) 100vw, 925px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_919046260 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_894428386 {\n  padding-top: 60px;\n  padding-bottom: 60px;\n  background-color: rgb(16, 23, 98);\n}\n@media (min-width:550px) {\n  #section_894428386 {\n    padding-top: 70px;\n    padding-bottom: 70px;\n  }\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section\" id=\"section_625094216\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\t<div id=\"gap-991524836\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-991524836 {\n  padding-top: 30px;\n}\n<\/style>\n\t<\/div>\n\t\n<div class=\"row\" style=\"max-width:1200px\" id=\"row-934102869\">\n\n\t<div id=\"col-1851566283\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1609635885\">\n\t\t\t\t\t\t<div data-animate=\"flipInX\">\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1216\" height=\"672\" src=\"https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/condenser-11.jpg\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/condenser-11.jpg 1216w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/condenser-11-300x166.jpg 300w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/condenser-11-1024x566.jpg 1024w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/condenser-11-768x424.jpg 768w\" sizes=\"auto, (max-width: 1216px) 100vw, 1216px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t<\/div>\t\t\t\t\t\t\n<style>\n#image_1609635885 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1851566283 > .col-inner {\n  padding: 0px 0px 0px 1px;\n}\n@media (min-width:850px) {\n  #col-1851566283 > .col-inner {\n    padding: 0px 50px 50px 0px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\t<div id=\"col-1088837780\" class=\"col medium-6 small-12 large-6\"  data-animate=\"bounceInLeft\">\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p style=\"text-align: justify;\">Copper tubes used in condensers have a diameter of 3\/4 inch, are grooved, and have various standards and FPI (fins per inch) values. Their thickness, ranging from 1 to 1.43 mm, depends on customer requirements and design specifications. <\/p>\n<p>Copper tubes in evaporators have diameters of 7, 9.52, 12, and 15.87 mm and can be plain or grooved, depending on customer requirements and design specifications. Their thickness varies from 0.63 to 1.24 mm.<\/p>\n<\/p>\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1088837780 > .col-inner {\n  padding: 0px 0px 0px 0;\n}\n@media (min-width:550px) {\n  #col-1088837780 > .col-inner {\n    padding: 50px 0px 0px 20px;\n  }\n}\n@media (min-width:850px) {\n  #col-1088837780 > .col-inner {\n    padding: 0px 0px 0px 50px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_625094216 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section\" id=\"section_1415162168\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row align-middle align-center\" style=\"max-width:1200px\" id=\"row-1342545502\">\n\n\t<div id=\"col-1764394263\" class=\"col medium-8 small-12 large-6\"  data-animate=\"bounceIn\">\n\t\t\t\t<div class=\"col-inner text-left\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"text-839078324\" class=\"text\">\n\t\t\n\t\t\n<style>\n#text-839078324 {\n  font-size: 1.1rem;\n}\n<\/style>\n\t<\/div>\n\t\n\t<div id=\"text-2077986194\" class=\"text\">\n\t\t\n<p style=\"text-align: justify;\">The type of grooves in evaporator and condenser tubes can vary based on design requirements and customer preferences, including GEWA K, GEWA KS, GEWA B models with different FPI values, as well as various CUPPRO FIN types.<\/p>\n<p>The type of shell used depends on the design requirements and can be seamless stainless steel or welded carbon steel. The shell thickness is determined based on the type of refrigerant, pressure, and corrosiveness of the secondary fluid, with a minimum thickness of 5 mm.<\/p>\n<p style=\"text-align: justify;\">All flanges used are of the RF type and CLASS 150 or 16PN. Higher classes can be used based on design requirements or customer specifications. <\/p>\n<\/p>\n\t\t\n<style>\n#text-2077986194 {\n  color: rgb(255,255,255);\n}\n#text-2077986194 > * {\n  color: rgb(255,255,255);\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1764394263 > .col-inner {\n  padding: 5% 5% 5% 5%;\n  margin: -42px -42px 0px 0px;\n}\n@media (min-width:550px) {\n  #col-1764394263 > .col-inner {\n    margin: 0px 0px 0px 0px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\t<div id=\"col-656176613\" class=\"col medium-5 small-12 large-5\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1290352744\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"925\" height=\"790\" src=\"https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/condenser-12.jpg\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/condenser-12.jpg 925w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/condenser-12-300x256.jpg 300w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/condenser-12-768x656.jpg 768w\" sizes=\"auto, (max-width: 925px) 100vw, 925px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1290352744 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1415162168 {\n  padding-top: 40px;\n  padding-bottom: 40px;\n  background-color: rgb(129, 195, 45);\n}\n@media (min-width:550px) {\n  #section_1415162168 {\n    padding-top: 80px;\n    padding-bottom: 80px;\n  }\n}\n@media (min-width:850px) {\n  #section_1415162168 {\n    padding-top: 10px;\n    padding-bottom: 10px;\n  }\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section\" id=\"section_53889700\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row align-middle align-center\"  id=\"row-1357741499\">\n\n\t<div id=\"col-294817021\" class=\"col medium-10 small-12 large-10\"  >\n\t\t\t\t<div class=\"col-inner text-center\"  >\n\t\t\t\n\t\t\t\n<p>All heat exchangers manufactured by Asamobadel Caspian have a 12-month warranty against defects or faults due to manufacturing quality. Design and manufacturing standards for heat exchangers are not necessarily limited to the aforementioned codes, and other conditions may be considered as design boundaries and inputs.<\/p>\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_764340111\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1909\" height=\"950\" src=\"https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/oil-cooler-08.jpg\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/oil-cooler-08.jpg 1909w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/oil-cooler-08-300x149.jpg 300w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/oil-cooler-08-1024x510.jpg 1024w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/oil-cooler-08-768x382.jpg 768w, https:\/\/amkahex.com\/wp-content\/uploads\/2023\/09\/oil-cooler-08-1536x764.jpg 1536w\" sizes=\"auto, (max-width: 1909px) 100vw, 1909px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_764340111 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t<div id=\"text-744273237\" class=\"text\">\n\t\t\n<p style=\"text-align: left;\">Materials:<\/p>\n<p style=\"text-align: left;\">Asamobadel Caspian, utilizing the latest standards and expertise in heat exchanger design and manufacturing, offers a variety of materials based on the product&#8217;s application, such as operating pressure and temperature, corrosiveness of the circulating fluid, and daily service hours, with a focus on optimizing dimensions, cost, and the useful life of heat exchangers.<\/p>\n<p style=\"text-align: left;\">\u25cf Tubes: Commonly made of alloyed copper with various thicknesses and sizes, such as 3\/8, 5\/8, and 3\/4 inches.<\/p>\n<p style=\"text-align: left;\">\u25cf Baffles and supports: Made of materials such as PP, PE, UPVC, SS316L, SS304, CU, and galvanized steel.<\/p>\n<p style=\"text-align: left;\">\u25cf Tube sheets and covers: Typically made of carbon steel, stainless steel, or alloy steel (for specific media in petrochemical and oil and gas plants).<\/p>\n<p style=\"text-align: left;\">\u25cf Shell: Typically made of carbon steel or stainless steel.<\/p>\n<p style=\"text-align: left;\">\u25cf Nozzles and headers: Made of carbon steel, ductile iron, or brass forgings.<\/p>\n<p style=\"text-align: left;\">\u25cf Connections: Flanged, threaded, or coupled.<\/p>\n\t\t\n<style>\n#text-744273237 {\n  text-align: right;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_53889700 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n<\/style>\n\t<\/section>\n\t\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"footnotes":""},"class_list":["post-1442","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/amkahex.com\/en\/wp-json\/wp\/v2\/pages\/1442","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/amkahex.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/amkahex.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/amkahex.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/amkahex.com\/en\/wp-json\/wp\/v2\/comments?post=1442"}],"version-history":[{"count":3,"href":"https:\/\/amkahex.com\/en\/wp-json\/wp\/v2\/pages\/1442\/revisions"}],"predecessor-version":[{"id":1514,"href":"https:\/\/amkahex.com\/en\/wp-json\/wp\/v2\/pages\/1442\/revisions\/1514"}],"wp:attachment":[{"href":"https:\/\/amkahex.com\/en\/wp-json\/wp\/v2\/media?parent=1442"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}